Documentation - Limelight XE™ - Reference - Objects
HID® EDGE EVO® Hi-O EWM Reader Module
ParentParent object that owns this object
GUIDObject's Globally Unique Identifier
{E6D14395-1400-0380-0100-XXXXXXXXXXXX}
OwnerModule or driver that owns this object
VersionMinimum software version that supports this object
Description
The HID® EDGE EVO® EWM Reader Module properties allow the user to set up various aspect of reader operation (e.g. reader type such as Weigand). Use this object to setup the reader for the specific application.
PropertiesThis object's unique properties or settings
Name |
Type |
Level |
R/W |
Description |
AlarmState |
Enumeration |
Admin |
R/W |
State of reader alarm (Armed, Alarm, Disabled, Unknown) |
Description |
String |
Admin |
R/W |
Description for the reader (e.g. Back Door) - defaults to the model name |
DeviceID |
Integer |
Admin |
R/O |
Hi-O bus device ID |
FirmwareRevision |
String |
Admin |
R/O |
Reader module firmware revision |
Location |
String |
Admin |
R/W |
Optional string for user (useful for room or building coordinates) |
LockState |
Enumeration |
Admin |
R/W |
Lock state of the door the reader is connected to (Locked, Unlocked Timed, Unlocked, Held, Alarm, Unknown) |
ReaderAliveEnable |
Boolean |
Admin |
R/W |
Heart beat to indicate reader is operational when true |
ReaderAliveMsg |
Integer |
Admin |
R/W |
Internal message sent to indicate reader is alive (default is 170) |
ReaderAliveTime |
Integer |
Admin |
R/W |
Time in milliseconds before reader is considered dead (default is 255) |
ReaderBeeperOn |
Boolean |
Admin |
R/W |
Controls the state of the reader's beeper (true=on, false=off) |
ReaderDataHold |
Boolean |
Admin |
R/W |
|
ReaderID |
Integer |
Admin |
R/O |
Reader ID assigned in the Readers file in the controller |
ReaderKeypad |
Boolean |
Admin |
R/W |
When set true indicates to the system the reader has a keybad |
ReaderLEDColor |
Enumeration |
Admin |
R/W |
Allows forcing the LED to a specific color (black - controlled by system) |
ReaderPINTimeOut |
Integer |
Admin |
R/W |
Timeout in seconds to allow user to enter a PIN |
ReaderReportEnable |
Boolean |
Admin |
R/W |
|
ReaderType |
Enumeration |
Admin |
R/W |
Reader encoding type (Clock and Data, Weigand) |
ReaderZoneID |
Integer |
Admin |
R/W |
The universal zone ID where this reader is located |
Title |
String |
Admin |
R/W |
Node title used in component view (defaults to "EWM Hi-O Reader" followed by the device ID) |